Brands |
N/A Ceramaseal® |
Installation |
N/A ConFlat Flange |
Installation Size |
N/A NW16CF |
Flange Size |
N/A 1-1/3 in |
American National Standards Institute (ANSI) Type |
N/A T |
Number of Pairs |
N/A 1 |
Temperature Range |
N/A -269 to 450 ºC |
Electro Motive Force (emf) |
N/A -5.60 to 17.82 mV |
Pressure at 20 Degree Celsius (ºC) Temperature |
N/A 1250 psi86 bar |
Thermocouple Materials |
N/A Constantan Copper |
Shell Material |
N/A 304 Stainless Steel |
Insulation Material |
N/A Alumina Ceramic |
Magnetic Material |
N/A false |
Extreme/Custom Design |
N/A
|
Applications |
N/A
A few of the many applications in which these thermocouples are commonly used are:
|
New Products |
N/A
|
Additional Information |
N/A
External instrumentation can then evaluate the strength of the emf that is proportional to the temperature at the thermocouple bead, thus yielding a temperature measurement. The Ceramaseal® thermocouple feed throughs provide the necessary electrical isolation and a hermetic seal. For refractory and noble metal thermocouples, Ceramaseal® products use compensating wires. The junction between the compensating wires and the true thermocouple conductor material must be thermally shielded and not exceed 250 ºC. |