Print Back

An assembly which provides for the transfer of electrical power, gases or fluids from outside a hermetic chamber to the inside. Feedthroughs can provide both a hermetic seal and electrical isolation from the chamber wall. Feedthroughs are sometimes referred to as 'pass-throughs'.
CeramTec feedthroughs provide the solutions for applications requiring hermeticity and electrical isolation.

 

Up to 2 Kilovolt (kV) Direct Current (DC) Voltage Rating, Up to 16 Ampere (A) Conductor Current Rating, and 1 to 8 Pin Instrumentation/Power Feedthroughs
Unit of Measure
1 2 

Item #

Item Name

Direct Current (DC) Voltage Rating

Temperature Range

Conductor Current Rating

Conductor Material

17007-04-KF N/A 4 Pin and 16 Ampere (A) Conductor Current Rating and International Organization for Standardization (ISO) Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -25 to 205 ºC N/A 16 A N/A Copper
17008-01-KF N/A 8 Pin and 1.1 Ampere (A) Conductor Current Rating and International Organization for Standardization (ISO) Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -25 to 205 ºC N/A 1.1 A N/A 304 Stainless Steel
17008-02-KF N/A 8 Pin and 5 Ampere (A) Conductor Current Rating and International Organization for Standardization (ISO) Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -25 to 205 ºC N/A 5 A N/A Nickel
17008-03-KF N/A 8 Pin and 8.5 Ampere (A) Conductor Current Rating and International Organization for Standardization (ISO) Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -25 to 205 ºC N/A 8.5 A N/A Molybdenum
17008-04-KF N/A 8 Pin and 16 Ampere (A) Conductor Current Rating and International Organization for Standardization (ISO) Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -25 to 205 ºC N/A 16 A N/A Copper
17046-01-CF N/A 2 Pin and 1.1 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 1.1 A N/A 304 Stainless Steel
17046-02-CF N/A 2 Pin and 5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 5 A N/A Nickel
17046-03-CF N/A 2 Pin and 8.5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 8.5 A N/A Molybdenum
17046-04-CF N/A 2 Pin and 16 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 16 A N/A Copper
17048-01-CF N/A 4 Pin and 1.1 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 1.1 A N/A 304 Stainless Steel
17048-02-CF N/A 4 Pin and 5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 5 A N/A Nickel
17048-03-CF N/A 4 Pin and 8.5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 8.5 A N/A Molybdenum
17048-04-CF N/A 4 Pin and 16 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 2 kV N/A -269 to 450 ºC N/A 16 A N/A Copper
9340-06-CF N/A 8 Pin and 1.1 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -269 to 450 ºC N/A 1.1 A N/A 304 Stainless Steel
9340-01-CF N/A 8 Pin and 5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -269 to 450 ºC N/A 5 A N/A Nickel
9340-04-CF N/A 8 Pin and 8.5 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -269 to 450 ºC N/A 8.5 A N/A Molybdenum
9340-05-CF N/A 8 Pin and 16 Ampere (A) Conductor Current Rating and ConFlat Flange Installation Instrumentation/Power Feedthrough N/A 1.5 kV N/A -269 to 450 ºC N/A 16 A N/A Copper
Unit of Measure
1 2