
Item # |
Item Name |
Direct Current (DC) Voltage Rating |
Pressure at 20 Degree Celsius (ÂșC) Temperature |
Conductor Current Rating |
Housing Material |
List Price |
|---|---|---|---|---|---|---|
| 2779-06-W | N/A Single 304 Stainless Steel Tube Weld Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $171.60 |
| 2779-02-W | N/A Single Copper Tube Weld Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $126.30 |
| 2780-16-W | N/A Single 304 Stainless Steel Tube Weld Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A | N/A 304 Stainless Steel | $133.06 |
| 2780-02-W | N/A Single Copper Tube Weld Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A | N/A 304 Stainless Steel | $123.09 |
| 2780-01-W | N/A Single Copper Pin Weld Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A 330 A | N/A 304 Stainless Steel | $143.64 |
| 16614-02-KF | N/A Single 304 Stainless Steel Tube NW16KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $224.25 |
| 16614-05-KF | N/A Single Copper Tube NW16KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $178.95 |
| 14308-06-KF | N/A Dual 304 Stainless Steel Tube NW40KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $389.09 |
| 14308-05-KF | N/A Dual Copper Tube NW40KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $298.49 |
| 17091-05-KF | N/A Single 304 Stainless Steel Tube NW16KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $185.72 |
| 17091-06-KF | N/A Single Copper Tube NW16KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $175.74 |
| 17091-04-KF | N/A Single Copper Pin NW16KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A 330 A | N/A 304 Stainless Steel | $196.30 |
| 17093-05-KF | N/A Dual 304 Stainless Steel Tube NW50KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $310.01 |
| 17093-06-KF | N/A Dual Copper Tube NW50KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A | N/A 304 Stainless Steel | $294.25 |
| 17093-04-KF | N/A Dual Copper Pin NW50KF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A | N/A 330 A | N/A 304 Stainless Steel | $331.17 |
| 7161-02-CF | N/A Single 304 Stainless Steel Tube NW16CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $219.12 |
| 7161-05-CF | N/A Single Copper Tube NW16CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $173.85 |
| 6700-08-CF | N/A Single 304 Stainless Steel Tube NW35CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $218.29 |
| 6700-05-CF | N/A Single Copper Tube NW35CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $172.99 |
| 16705-04-CF | N/A Dual 304 Stainless Steel Tube NW35CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $389.88 |
| 16705-02-CF | N/A Dual Copper Tube NW35CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.25 Inch (in) Conductor Diameter | N/A 8 kV | N/A 750 psig52 bar | N/A | N/A 304 Stainless Steel | $299.28 |
| 17099-01-CF | N/A Single 304 Stainless Steel Tube NW16CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A | N/A 304 Stainless Steel | $170.20 |
| 17099-02-CF | N/A Single Copper Tube NW16CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A | N/A 304 Stainless Steel | $160.23 |
| 17099-06-CF | N/A Single Copper Pin NW16CF Flange Installation High Power/Liquid Cooled Feedthrough with 0.375 Inch (in) Conductor Diameter | N/A 8 kV | N/A 500 psig34 bar | N/A 330 A | N/A 304 Stainless Steel | $180.78 |